Homes Qualifying for Federal Tax Credit
CDS Construction

- Location: Mansfield, MA
- Rater: Conservation Services Group
- Home Size: 3,458 sq ft
- Foundation: Slab on grade
- Slab Insulation: R-15 perimeter, R-5 under slab
- Air Leakage: .83 ACH 50
- Ventilation: Mechanical
- Windows: U .33 - SHGC .30
- Window to Wall: Less than 12%
- Heater: 94% AFUE
- Walls: R-23
- Ceiling: R-38